LRT1000HL-BE10CM05T12A Specifications

Download Datasheet
Accuracy (unidirectional) 450 µm (0.017716")
Repeatability < 4 µm (< 0.000157")
Minimum Incremental Move 6.5 µm
Backlash < 25 µm (< 0.000984")
Flatness of Travel < 10 µm (< 0.000394")
Straightness of Travel < 50 µm (< 0.001968")
Pitch Error 0.015° (0.262 mrad)
Roll Error 0.02° (0.349 mrad)
Yaw Error 0.03° (0.523 mrad)
Peak Thrust 1440 N (322.9 lb)
Maximum Axial Brake Force 1200 N (269.8 lb)
Maximum Continuous Thrust 440 N (98.7 lb)
Back-driving Force* (± 50%) 140 N (31.4 lb)
Maximum Centered Load 2940 N (659.3 lb)
Maximum Moment (Pitch) 70 N⋅m (51.7 lb⋅ft)
Maximum Moment (Roll) 120 N⋅m (88.56 lb⋅ft)
Maximum Moment (Yaw) 70 N⋅m (51.66 lb⋅ft)
Stiffness (Pitch) 1400 N⋅m/° (12 µrad/N⋅m)
Stiffness (Roll) 700 N⋅m/° (25 µrad/N⋅m)
Stiffness (Yaw) 1200 N⋅m/° (15 µrad/N⋅m)
Maximum Speed 240 mm/s (9.449"/s)
Minimum Speed 0.000186 mm/s (0.000007"/s)
Speed Resolution 0.000186 mm/s (0.000007"/s)
Typical Velocity Stability ± 2% at 100 mm/s with a 5 kg payload
Encoder Type Rotary quadrature encoder (single-turn absolute)
Encoder Resolution 4096 CPR (16384 states/rev)
Encoder Count Size 305.176 nm
Limit or Home Sensing Encoder index signal and magnetic home sensor
Linear Motion Per Motor Rev 5 mm (0.197")
Motor Type Brushless DC (3 phase)
Motor Rated Current 5000 mA
Motor Winding Resistance 0.55 ohms line-to-line
Motor Winding Inductance 0.68 mH line-to-line
Motor Connection M12 T-code (motor) and D-sub 26 (sensors)
Guide Type Recirculating Ball Linear Guide
Mechanical Drive System Precision ball screw

* These are our direct prices in USD to customers in North America. If you are in Canada, click the Canadian flag icon at the top right of the page to see CAD prices. If you are in a country outside North America where we have an exclusive distributor, please check with the distributor for pricing. Distributor prices might be slightly higher to factor in shipping and import fees. Click here for a list of Zaber's Distributors.

Specification Charts & Notes

Thrust or torque is a function of speed. The values given above are maximums. These values cannot both be achieved simultaneously (i.e. at maximum speed, the unit will not produce maximum thrust).

Thrust Speed Performance

LRTxxxxHL-E10CM05T1xA Thrust-Speed Performance

Acceleration

LRTxxxxHL-E10CM05T11A Acceleration vs Payload

Minimum Incremental Move

LRTxxxxHL-E10CM05T11A with X-MCCx 6200 nm Step - Typical Minimum Incremental Move

Other

LRTxxxxHL-E10M05T11A with X-MCCx - Typical Velocity Stability and Following Error

Bearing Lifetime

Photo of LRT_lifetime
Photo of Typical LRTxxxxH Ball Screw Lifetime