Template:X-Series/Precautions/X-LSQ-EC

From ZaberWiki
Jump to navigation Jump to search

Lubrication of Linear Guide

The {{{Device}}} carriage is supported by an integrated recirculating ball bearing linear guide which requires lubrication in order to achieve the longest possible lifetime. At the rated load of the device, it is recommended to re-lubricate at a 500 km service interval. For applications in dirty environments or applications with extremely high duty cycles, more frequent inspection and lubrication is recommended. We recommend using 0.1 cm³ (1 mL) of a NLGI Grade 2, lithium soap based grease in each grease port. The grease ports are located on both ends of the carriage (see pictures below) and both sides of the belt. Simply inject about 0.1 cm³ of grease into each port. Cycle the stage through its travel several times and wipe off any excess grease from the rails. All guides come pre-lubricated and are ready to go out of the box. This grease is only intended for lubricating ball bearing guide, and is not suitable for use on any other locations on the stage.

Noise Emissions

The A-weighted emission sound pressure level (SPL) of this device does not exceed 70 dB(A) during intended use.