Dust Cover Installation and Removal
The {{{Device}}} stage comes with a removable dust cover. Temporary removal is required to access stage mounting holes and to re-lubricate the linear bearings.
Loosen the two set screws on the motor end plate using a 1.5 mm hex key.
Remove the two M3 screws on the end of the LSQ device.
Slide the dust cover and spacer plate out from the end plate and through the carriage. The carriage top can remain in place or be removed.
To reinstall the dust cover, simply slide the cover back into place and tighten the two M3 set screws on the motor end plate using a 1.5 mm hex key.
Slide the spacer plate back under the end of the dust cover and align the M3 holes. Reinstall the two M3 screws using 2 mm hex key.
If the stage top was removed, install the four M3 x 16 mm screws. Make sure the stage top edge is aligned to the carriage edge. Tighten screws to 1.3 Nm using a 2.5 mm hex key.