Indicators
[[File:{{{Connector}}}_Indicators_w500.jpg|500px|link=|{{{Device}}} Indicators]]
- PWR (Green) - Power.
- On: Controller is operational.
- Blinking at 2Hz: The power supply voltage or device temperature is out of range.
- Fading in and out slowly: The device is parked. See the tools parking (T:65) command.
- ERR (Red) - Error.
- On/blinking: Controller has lost its settings, or an error has occurred. Please contact Zaber Technical Support.
- MOT (Yellow) - Communication/Busy.
- On: Device is moving, or data is being transferred.
- Blinking: Device is under manual control via the knob (in Velocity mode). The blinking rate is proportional to movement speed.
- Blinking at fixed rate: Packet corruption has occurred for ASCII commands sent with a checksum.
- ENC (Blue) - Slip/Stall.
- On: The device is slipping.
- On-Off cycle every 2 sec: The device has stalled and stopped.
- Flashes: The stationary device has been forced out of position (2 short flashes every 1 sec), or the encoder has encountered a read error and raised the FQ warning flag (5 short flashes every 2 sec).