Disclaimer

Zaber’s products are not intended for use in any critical medical, aviation, or military applications or situations where a product's use or failure could cause personal injury, death, or damage to property. Zaber disclaims any and all liability for injury or other damages resulting from the use of our products.

Precautions

Zaber’s motion control devices are precision instruments and must be handled with care. In particular, moving parts must be treated with care. Avoid axial loads in excess of the rated thrust load, axial and radial impact, dust and other contaminants and damage to the drive components. These will reduce the performance of the device below stated specifications.


Conventions used throughout this document

  • Fixed width type indicates communication to and from a device. The symbol indicates a carriage return, which can be achieved by pressing enter when using a terminal program.
  • An ASCII command followed by (T:xx) indicates a legacy T-Series Binary Protocol command that achieves the same result. For example,
    move abs 10000 (T:20:10000) shows that a move abs ASCII command can also be achieved with Binary command number 20.
Not all ASCII commands have an equivalent Binary counterpart.

Quick Tutorial

We recommend using Zaber Console to communicate with the device(s). For other software options, see the Software page. Please refer to the ASCII Protocol Manual and/or Binary Protocol Manual for more detailed information on the available commands.

Initial Set-up

X-NA-E Setup


  1. Daisy chain all integrated devices together using the RS-232 "Prev" and "Next" connectors (see Daisy-Chaining Devices for more details). Next, supply power to one or more devices. Many products share power through the daisy-chain cables. The power indicator on each should light up.
  2. Turn the knob to move a positioner. Most positioners will only move in one direction until they reach a home sensor at one limit of travel. Then they will move in both directions over full travel.
  3. Download and install Zaber Console. Start Zaber Console and select the communications port the first controller is connected to. For instructions on how to find the available communication ports on your system, please refer to: Appendix A - Available Communications Ports.
  4. From the Console, issue a renumber (T:2) command to all devices (Zaber Console may prompt you to do this also). The first device in the chain (closest to the computer) will become Device 1, the next will become Device 2, and so on.



Initialization

Every time the device is powered up or reset, the positioner should be returned to the home position. This is achieved by sending the home (T:1) command to the individual unit or all units. Until this is done, most positioners will only allow motion in one direction, towards the sensor.

If it is not possible in your application to home the positioner after every power-up, see the tools parking (T:65) command. Parking allows the device to be turned off and then used at a later time without first having to home the axes.

Using the Device

Several commonly used ASCII commands, and their Binary equivalents, are shown below. For a full list of available commands, please refer to the Command Reference section below.

Command Description
/1 1 get pos↵ (T:60) Query the current position of Device #1 Axis #1.
/1 1 move abs 10000↵ (T:20:10000) Move Device #1, Axis #1 to position 10000 microsteps.
/2 1 move rel -12800↵ (T:21:-12800) Move Device #2, Axis #1 in the negative direction by 12800 microsteps.
/1 stop↵ (T:23) Decelerate and stop ALL axes on Device 1.
An axis number of 0 or no axis number implies all axes on the device, or the device itself.
/move vel 153600↵ (T:22:153600) Move ALL devices and ALL axes in the positive direction at the speed 153600.
A device address of 0 or no device address implies all devices in the chain.

Modifying Device Settings

Here are some examples if you would like to customize particular device settings. Refer to the ASCII Settings or Command Reference section for detailed descriptions of each setting.

Command Description
/1 set maxspeed 100000↵ (T:42:100000) Set the speed of all axes on the device.
/1 get maxspeed↵ (T:53:42) Query the axes' speed.
/1 system restore↵ (T:36) Restore all the settings of Device 1 to the default.

Built-In Help

Zaber X-Series devices feature a built-in help guide, providing a quick and easy reference for all Commands and Settings that the device has. To access the help, send: /1 help (for help with Device 1). The device number must be specified in the help command. This feature is only available in the ASCII protocol.

The device will respond with a detailed description on how to access specific information about commands and replies, as shown below:

@01 0 OK IDLE WR 0
#01 0 COMMAND USAGE:
#01 0  '/stop'     stop all devices
#01 0  '/1 stop'   stop device number 1
#01 0  '/1 2 stop'   stop device number 1 axis number 2
#01 0
#01 0 Type '/help commands' for a list of all top-level commands.
#01 0 Type '/help reply' for a quick reference on reply messages.
#01 0 Visit www.zaber.com/support for complete instruction manuals.

To access help for a specific command, for example the move command, send:

/1 help move↵
@01 0 OK IDLE -- 0
#01 0 move abs {x}             Move to absolute position
#01 0 move rel {x}             Move by relative position
#01 0 move vel {x}             Move at constant velocity
#01 0 move min                 Move to minimum position
#01 0 move max                 Move to maximum position

Device Overview

Connectors

All images are shown looking into the device.

Power

Terminal Connector Pin Description
1 24 - 48 V
2 Device GND

Note: As of February 2022, the power supplies Zaber provides for X-Series devices are isolated and thus the device is not connected to Earth ground.

Note: Prior to 2022, most power supplies provided for X-Series devices were non-isolated. Isolated units can be distinguished by the "S" suffix in their Zaber part number (eg. PS14S), which is marked on the label on the bottom of the power supply.

RS-232 Communications

M8 4-pin Connector Pin Previous Next
1 Power Power
2 Ground Ground
3 Receive Transmit
4 Transmit Receive

Default Settings:

  • Baud Rate: 115200
  • Protocol: Zaber ASCII

Specifications

  • Supported Protocols: Zaber ASCII, Zaber Binary
  • Supported Baudrates: 9600, 19200, 38400, 57600, 115200
  • Bits: 8
  • Parity: None
  • Stop Bits: 1
  • Flow Control: None




Indicators

Green - Power
  • On: Controller is operational.
  • Blinking at 2Hz: The power supply voltage or device temperature is out of range.
  • Fading in and out slowly: The device is parked. See the tools parking (T:65) command.
Red - Error
Yellow - Communication/Busy
  • On: Device is moving, or data is being transferred.
  • Blinking: Device is under manual control via the knob (in Velocity mode). The blinking rate is proportional to movement speed.
  • Blinking at fixed rate: Packet corruption has occurred for ASCII commands sent with a checksum.
Blue - Slip/Stall
  • On: The device is slipping.
  • On-Off cycle every 2 sec: The device has stalled and stopped.
  • Flashes: The stationary device has been forced out of position (2 short flashes every 1 sec), or the encoder has encountered a read error and raised the FQ warning flag (5 short flashes every 2 sec).

Installation

The X-NA-E can be connected to a computer as follows:

  1. Either plug the M8 to D-SUB serial adaptor (X-SDC) into the computer's serial port, or the M8 to USB adaptor (X-USBDC) into one of your computer's USB ports, then attach the device to the adaptor. For the USB adaptor, new computers will often be able to install the necessary drivers automatically when the cable is plugged in for the first time. If the computer reports that the driver installation was unsuccessful, you can download the drivers for Windows, Mac, or Linux here. Installation instructions and troubleshooting information are available for each operating system here. You may need to use a cable extension to reach your computer. There is no need to power-down or reboot the computer.
  2. Connect the power plug of your power supply to the power connector of the unit. The green LED should light up indicating the unit has power.
  3. Additional devices can simply be daisy-chained to the first. See Daisy-Chaining Devices below.
  4. Install software from the Software page. For the initial setup, using Zaber Console is recommended.

X-NA-E PC Connection Setup

As a simple first test, try entering:

/renumber↵ (T:2)
/1 home↵ (T:1)
/1 move rel 10000↵ (T:21:10000)

The parameter of 10000 in the move command above specifies 10000 microsteps. To see the microstep size (default resolution) for the positioner and how it translates to displacement, first go to the product overview page, find your product, click through to the product's webpage, and click on the "Series Specs" tab. The microstep size (default resolution) will be shown in the list of product specs either in the "Group Specifications" section or the "Comparison" section.

Daisy-Chaining Devices

Multiple devices can be connected together in a chain through the Prev and Next connectors. This allows any number of devices to be controlled from a single connection to a computer, reducing cabling demands. In addition, X-Series devices carry power through the daisy chain, so in most cases a power supply only needs to be connected to one device in the chain. Whenever a device is added or removed from a chain, a renumber (T:2) command should be sent to prevent device-address conflicts.

Daisy Chain Setup

To daisy-chain X-Series devices with T-Series and A-Series devices:

  • Ensure all devices are set to the same communication protocol and baud rate before connecting them. If any T-Series devices will be in the chain, then the communication protocol must be Binary at 9600 baud rate.
  • Connect any X-Series devices at the start of the chain (closest to the computer). This configuration will reduce the number of adaptor cables required.
  • Connect a T-XDC (or S-XDC for daisy-chaining an A-MCB2) adaptor cable to the Next port of the last X-Series device in the chain, and to the Prev port of the T-Series or A-Series device.
  • Power supplied to an X-Series device will not be transmitted to any T-Series or A-Series devices in the chain.
  • Contact Zaber Technical Support for assistance selecting connecting cables when daisy-chaining multiple series.


Manual Control

Most X-Series motion control products have an integrated, depressible knob with 20 detents per revolution, allowing axes to be controlled without the use of a computer. There are two manual movement modes available: Velocity and Displacement. Switch between these modes by holding down the knob for 1 second or by configuring the knob.mode (T:109) setting.

On power-up, the axis will only travel towards the motor from its start-up position until the home position is reached. Once the axis has been homed, the full range of travel becomes available.

Velocity Mode

Turn the knob clockwise to move the axis in the positive direction (extend) or counter-clockwise for negative direction (retract). Each detent of the knob increases the speed of the carriage.

There are 16 speeds in each direction. The velocity profile and maximum speed can be configured via the knob.speedprofile (T:112) and knob.maxspeed (T:111) settings. The axis stops and resets the knob upon arriving at the end of travel.

Displacement Mode

Turn the knob clockwise to move the axis in the positive direction (extend), counter-clockwise for negative direction (retract). Each detent of the knob moves the axis a fixed number of microsteps, specified by the knob.distance (T:110) setting. If knob.distance (T:110) is set to 0, each detent of the knob will move to the next index position, similar to move index (T:78) movements. The axis moves at the speed specified by the maxspeed (T:42) setting, or the slower of maxspeed (T:42) and limit.approach.maxspeed (T:41) if the axis has not been homed. If there are fewer than knob.distance (T:110) microsteps to the end of travel and another move is requested, the axis will move to the end of travel and then stop.

Summary of knob functionality

  • Turning the knob:
    Moves the axis in the direction of knob turn.
  • Pressing the knob:
    Decelerates and stops the axis (identical to a stop (T:23) command).
    Instantly stops the axis, if the axis is already decelerating.
  • Pressing and holding the knob for 1 sec:
    Toggles between Velocity Mode and Displacement Mode.

Trajectory Control and Behaviour

This section describes the behaviour of the axis trajectory when a movement command is issued.

Software Position Limits

The travel range of the axis is limited by the Minimum Position and Maximum Position settings. The factory settings for the axis are configured to match the physical travel range. If a customized range is desired, it can be changed by configuring the limit.min (T:106) and limit.max (T:44) settings to appropriate values.

Minimum Position
When the Current Position is less than the Minimum Position value, the axis cannot move in the negative direction(towards the motor).
Maximum Position
When the Current Position is greater than the Maximum Position value, the axis cannot move in the positive direction(towards the motor).


Movement Speed

The movement speed of the axis depends on axis status and various speed settings. If the axis has not been initialized by the home (T:1) command or by moving towards the home end of the axis, movement speed will be constrained to fail-safe values. The home status of the axis can be determined by reading the limit.sensor.triggered (T:53) setting (the binary command additionally requires a value of 103).

Movement speed of the axis is specified below:

move vel (T:22)
The axis will move at the specified speed regardless of home status.
Knob movement in Velocity Mode
The axis will move at the specified speed regardless of home status.
The speed is specified by the knob.speedprofile (T:112) and knob.maxspeed (T:111) settings.
Other movement commands - when the axis has not been homed
The axis will move at the slower of the maxspeed (T:42) and limit.approach.maxspeed (T:41) settings.
Other movement commands - when the axis has been homed
The axis will move at the speed specified by the maxspeed (T:42) setting.



|}}


Troubleshooting X-Series Motion Devices

The following sections contain tips for troubleshooting common problems. If the device is unable to communicate, and it is operating erratically, a manual factory reset can be performed through the following steps. Note that this will reset most settings.

  1. Power Off the device
  2. Push and hold the knob for the first Axis (if applicable)
  3. Power On the device
  4. Continue to hold the knob in until the blue LED is lit (~5 seconds), then release.

The device has been returned to its factory defaults and can be configured as per the steps in Initial Setup.

Front Panel Indicators

Green LED On
The device is powered on and is operating normally.
Green LED Fades In and Out
The device is parked.
Issue a tools parking unpark (T:65) command, or home (T:1) the device.
Green LED Flashes Slowly
The operating conditions of the device are outside of the recommended range.
This will occur when the supply voltage is either over or under the recommended range, the internal temperature has exceeded the set limit, or the driver has been disabled. Check the following:
  • The input voltage is within the operational range of the device. This can be read from the device with the get system.voltage command.
  • The device temperature is within range. This can be read from the device with the get system.temperature command.
  • The driver is not disabled. If the driver is disabled the result of the warnings command will contain the FD flag.
Green LED Off
The device is not powered.
Check the supply connections and power adaptor for correct operation.
Red LED On or Flashing.
A critical error has occurred.
Please contact Zaber Technical Support.
Blue LED On or Flashing.
The axis has slipped or stalled.
Please see the Slipping and Stalling section below.
Yellow LED Always Off or Flashes but No Reply.
There are communication errors.
Please see the Communication Errors section below.

Manual Control

Turning the knob either way results in no movement
The knob may have been disabled.
Check that the knob.enable (T:107) setting is correct.
Restore the default parameters through the system restore (T:36) command.
The axis won't cover the full range of travel.
The axis hasn't been homed.
Turn the knob anti-clockwise until the axis reaches the fully retracted position (closest to the motor). The axis will home and the full range of travel available.

Unexpected Behaviour

The axis doesn't respond to a move command.
The axis needs to be homed before use.
Send the home (T:1) command.
The axis is moving on its own and running against the ends of travel.
The position encoder has de-synchronized.
Reset the device by power cycling it or sending the system reset (T:0) command, then re-initialize it with the home (T:1) command.
The axis is moving very slowly. It used to move faster.
The speed settings may have been changed inadvertently.
Send a system restore (T:36) command.
The axis makes louder than normal noise during travel and is frequently slipping.
This condition happens if the thrust needed is more than the thrust available from the axis.
Check the following:
  • The force on the axis is less than the maximum thrust.
  • The voltage matches the specified voltage. Read the voltage using the get system.voltage command. Voltage less than the specified voltage for the device will reduce the positioner’s maximum thrust.
Test the following:
  • Try a slower target velocity. Stepper motors produce more thrust when moving slowly.
  • Try a lower acceleration and deceleration.
  • Clean the screw and lightly re-grease it with a grease that does not degrade plastics.
The axis has repeatability errors smaller than 4 full steps.
If steps aren't being skipped, friction or loose parts may still cause some variation when returning to a position.
Please contact Zaber Technical Support.
The axis doesn't cover the full range of travel, or runs into the end.
A setting might have been inadvertently changed.

Communication Errors

There is no communication with the device; the Yellow LED does not come on or flash.
There are several things that should be checked:
  • Make sure the correct serial port is selected. Try selecting other serial ports in the software.
  • Check the baud rate, hand shaking, parity, stop bit, etc. when configuring the serial communications software. The required settings are listed in the RS-232 Communications section above.
  • Make sure there are no bent pins in the ends of all the data cables
  • Make sure the device is powered. The Green LED should be on.
  • If the computer is a laptop running on batteries, try plugging in the power. Some laptops disable the serial ports when running on batteries.
  • Make sure a null modem adaptor or cable is not being used.
  • Make sure the correct adaptors(if any) are being used. Refer to the pinouts in the RS-232 Communications section above.
  • If the problem was encountered when trying to control the device with custom software, try using one of the demo programs from the Zaber website to verify that the hardware is functioning properly.
Two or more devices both respond to commands sent to device 1.
Most devices are shipped with their device number set as 1. If you connect the devices through Zaber Console, you will be prompted to renumber them. If you aren't able to install and open Zaber Console, send the renumber (T:2) command in the software you are using to set all of the device numbers to different values.
The Yellow LED comes on briefly when sending a command, but the device does not move and does not reply.
Check baud rate, hand shaking, parity, stop bit, etc. are set as per the RS-232 Communications defaults.
The device numbers may not be what is expected, issue a renumber (T:2) command. Make sure that the computer does not transmit anything else while the devices renumber.
If using the Binary Protocol, check the following:
  • 6 bytes are transmitted and that the device number and command are valid.
  • The software does not transmit any control characters such as line feed and spaces.
  • That the serial port is not configured with a termination character (it often defaults to linefeed).
If problems are encountered when using custom software, try using one of the demo programs from the Zaber website to verify that the hardware works.
The device does not behave as expected when software sends it a series of commands.
The computer might be set to Unicode. This is common for languages that use non-Latin based characters. Go to Control Panel/Regional and Language Options/Advanced. Select a language for non-unicode programs. This should be English or another Latin based character language.
Check what is being sent out of the serial port. stackoverflow.com has a list of some tools to monitor serial ports.
In Binary mode, the device does not send replies but otherwise works.
Auto-reply might have been disabled via T:101.
Send a system restore (T:36) command.
If the problem is encountered when trying to control the device with custom software:
  • Use a demo program from the Zaber website to verify that the hardware is functioning properly.
  • Make sure that the receiving part of the code or commercial package is correct.
  • Check the serial port settings are correct.
  • Check connectors for bent or broken pins.
In Binary mode, the device sometimes returns fewer than 6 bytes.
This typically indicates a problem with the serial port settings. Some serial ports are set to automatically recognize and remove specific control characters such as carriage returns when they appear in the RS-232 receive buffer.
Check that the settings are correct and are not removing or replacing characters.

Slipping and Stalling

The axis moves smoothly, but only moves for a short time then stops. The Blue LED is flashing but the axis is not actually slipping or stalling.
The internal encoder counter needs to be re-initialized. Reset the device by power cycling it or sending system reset (T:0) command, then re-initialize it with the home (T:1) command.
Ground the device and avoid operating it under statically noisy environment.
The axis makes noise but does not move. The Blue LED is flashing.
The axis is stalling.
Try removing all external loads. If the axis now extends and retracts normally, the problem is excessive load. Try to reduce the load and ensure the load is less than the maximum thrust. A higher thrust or torque can be achieved by lowering the speed of the axis using the maxspeed (T:42) setting.
If an axis is stalling with no external load at default speed and acceleration settings then it requires servicing.

Warranty and Repair

For Zaber's policies on warranty and repair, please refer to the Ordering Policies.

Standard products

Standard products are any part numbers that do not contain the suffix ENG followed by a 4 digit number. Most, but not all, standard products are listed for sale on our website. All standard Zaber products are backed by a one-month satisfaction guarantee. If you are not satisfied with your purchase, we will refund your payment minus any shipping charges. Goods must be in brand new saleable condition with no marks. Zaber products are guaranteed for one year. During this period Zaber will repair any products with faults due to manufacturing defects, free of charge.

Custom products

Custom products are any part numbers containing the suffix ENG followed by a 4 digit number. Each of these products has been designed for a custom application for a particular customer. Custom products are guaranteed for one year, unless explicitly stated otherwise. During this period Zaber will repair any products with faults due to manufacturing defects, free of charge.

How to return products

Customers with devices in need of return or repair should contact Zaber to obtain an RMA form which must be filled out and sent back to us to receive an RMA number. The RMA form contains instructions for packing and returning the device. The specified RMA number must be included on the shipment to ensure timely processing.

Email Updates

If you would like to receive our periodic email newsletter including product updates and promotions, please sign up online at www.zaber.com (news section). Newsletters typically include a promotional offer worth at least $100.

Contact Information

Contact Zaber Technologies Inc by any of the following methods:

Phone 1-604-569-3780 (direct)
1-888-276-8033 (toll free in North America)
Fax 1-604-648-8033
Mail #2 - 605 West Kent Ave. N., Vancouver, British Columbia, Canada, V6P 6T7
Web www.zaber.com
Email Please visit our website for up to date email contact information.

The original instructions for this product are available at https://www.zaber.com/manuals/X-NA-E.

Appendix A - Available Communications Ports

Finding Installed Serial Ports

Windows

  1. Open Search or Run from the Start Menu or Taskbar, type "Device Manager" and press enter.
    Win-serport-1.png
  2. Expand the Ports (COM & LPT) category.
    Win-serport-2.png
    • In this example there are two serial ports available (COM1 and COM15), which are both USB adaptors.

Linux

  1. Finding devices
    • Open a terminal and execute the following command:
    dmesg | grep -E ttyU\?S↵
    • The response will be similar to the following:
      [ 2.029214] serial8250: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A
      [ 2.432572] 00:07: ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A
      [ 2.468149] 0000:00:03.3: ttyS4 at I/O 0xec98 (irq = 17) is a 16550A
      [ 13.514432] usb 7-2: FTDI USB Serial Device converter now attached to ttyUSB0
    • This shows that there are 3 serial ports available: ttyS0, ttyS4 and ttyUSB0 (a USB adaptor)
  2. Checking port permissions
    • Using the ports found above, execute the following command
    ls -l /dev/tty{S0, S4, USB0}↵
    • The permissions, given below, show that a user has to be root or a member of the dialout group to be able to access these devices
      crw-rw---- 1 root dialout 4, 64 Oct 31 06:44 /dev/ttyS0
      crw-rw---- 1 root dialout 4, 68 Oct 31 06:45 /dev/ttyS4
      crw-rw---- 1 root dialout 188, 0 Oct 31 07:58 /dev/ttyUSB0
  3. Checking group membership
    groups↵
    • The output will be similar to the following:
      adm cdrom sudo dip plugdev users lpadmin sambashare
      Notice that dialout is not in the list
    • A user can be added to the dialout group with the following command
    sudo adduser $USER dialout↵
    • Group membership will not take effect until the next logon.

OSX

  1. Finding devices
    • Open a terminal and execute the following command:
    ls /dev/cu.*serial*
    • The response will be similar to the following:
      /dev/cu.usbserial-FTB3QAET
      /dev/cu.usbserial-FTEJJ1YW
    • This shows that there are two serial ports available, both of which happen to be USB adaptors.