Warning: This is an "include" page. As such, its contents may be included in multiple other pages. To see a list of all pages that include this page, click on "What links here" in the bottom left navbar. If you make changes to this page, be sure that your changes are appropriate to all pages on which this content will be included. You are also encouraged to review our Zaber Wiki Editing Guidelines. This header will not be included in other pages.

Instruction Name Set Move Tracking Period
Applies to A-Series and X-Series motorized devices
Firmware Version 6.xx
Command Number 117
Command Type Setting
Command Data Tracking Period in ms
Reply Data Tracking Period in ms
Safe to retry? Yes
Returns Current Position? No
Persistence Non-Volatile
Summary Sets the update interval between Move Tracking and Manual Move Tracking messages.

Use this command to configure the interval between each Move Tracking (Cmd 8) or Manual Move Tracking (Cmd 10) responses. The value is specified in milliseconds and the default setting is 250ms. The shortest possible tracking period is 10ms.

This setting is stored in non-volatile memory and will persist after power-down or reset.