T-Series/Commands/Set Minimum Position
Set Minimum Position - Cmd 106
Warning: This is an "include" page. As such, its contents may be included in multiple other pages. To see a list of all pages that include this page, click on "What links here" in the bottom left navbar. If you make changes to this page, be sure that your changes are appropriate to all pages on which this content will be included. You are also encouraged to review our Zaber Wiki Editing Guidelines. This header will not be included in other pages.
| Instruction Name | Set Minimum Position |
|---|---|
| Applies to | A-Series and X-Series motorized devices |
| Firmware Version | 6.xx |
| Command Number | 106 |
| Command Type | Setting |
| Command Data | Minimum Position |
| Reply Data | Minimum Position |
| Safe to retry? | Yes |
| Returns Current Position? | No |
| Persistence | Non-Volatile |
| Summary | Sets the minimum position the device is allowed to reach. |
A device within range of travel is not allowed to move below its Minimum Position. If the device Current Position is out of range and below Minimum Position, the device is not allowed to move in the negative direction. The default Minimum Position in most devices is 0.
Use this command to limit the range of travel to a value other than the default. Exercise caution when using this command, since it is possible to set the range to a value greater than the physical limits of the device.
Valid values can be any number from -1000000000 to 1000000000.
This setting is stored in non-volatile memory and will persist after power-down or reset.