T-Series/Commands/Set Knob Jog Size

From ZaberWiki
Jump to navigation Jump to search

Set Knob Jog Size - Cmd 110

Warning: This is an "include" page. As such, its contents may be included in multiple other pages. To see a list of all pages that include this page, click on "What links here" in the bottom left navbar. If you make changes to this page, be sure that your changes are appropriate to all pages on which this content will be included. You are also encouraged to review our Zaber Wiki Editing Guidelines. This header will not be included in other pages.

Instruction Name Set Knob Jog Size
Applies to A-Series and X-Series motorized devices
Firmware Version 6.xx
Command Number 110
Command Type Setting
Command Data Jog Size
Reply Data Jog Size
Safe to retry? Yes
Returns Current Position? No
Persistence Non-Volatile
Summary Sets the distance to travel for knob manual movement in displacement mode.

Use this command to set the number of microsteps per knob detent when the knob is turned in displacement mode.

Each detent of a knob turn moves the device for a fixed number of microsteps. The device stops if the number of microsteps left in the max/min range is less than the requested move command number.

The default setting for most devices sets a value such that one full cycle of the knob will result in one revolution of the stepper motor.

If this setting is set to 0, each step of the knob moves to the next or previous index position, similar to Move Index (Cmd 78) movements.

This setting is stored in non-volatile memory and will persist after power-down or reset.