T-Series/Commands/Return Stored Position
From ZaberWiki
[edit] Return Stored Position - Cmd 17
Warning: This is an "include" page. As such, its contents may be included in multiple other pages. To see a list of all pages that include this page, click on "What links here" in the bottom left navbar. If you make changes to this page, be sure that your changes are appropriate to all pages on which this content will be included. You are also encouraged to review our Zaber Wiki Editing Guidelines. This header will not be included in other pages.
| Instruction Name | Return Stored Position |
|---|---|
| Firmware Version | 5.04 and up |
| Command Number | 17 |
| Command Type | Command |
| Command Data | Address |
| Reply Data | Stored Position |
| Persistence | n/a |
| Summary | Returns the position stored in one of the 16 position registers for the device. |
Valid address values are 0 through 15, specifying one of 16 possible registers from which to retrieve the position. This command is used in conjunction with the Store Current Position (#16) and Move To Stored Position (#18) commands. Positions stored in the position registers are non-volatile and will persist after power-down or reset. All position registers are cleared by the Restore Factory Settings (#36) command.