T-Series/Commands/Return Setting

From ZaberWiki

Jump to: navigation, search

[edit] Return Setting - Cmd 53

Warning: This is an "include" page. As such, its contents may be included in multiple other pages. To see a list of all pages that include this page, click on "What links here" in the bottom left navbar. If you make changes to this page, be sure that your changes are appropriate to all pages on which this content will be included. You are also encouraged to review our Zaber Wiki Editing Guidelines. This header will not be included in other pages.

Instruction Name Return Setting
Firmware Version 5.00 and up
Command Number 53
Command Type Command
Command Data Setting Number
Reply Data Setting Value
Persistence n/a
Summary Returns the current value of the setting specified in the Command Data.

Valid setting numbers are the command numbers of any "Set..." instruction. The device will reply using the command number of the specified setting (as if a command to change the setting had just been issued) but the setting will not be changed.

For example, command #48 is the "Set Alias" instruction. Therefore if you wish to return the current value of the alias number, simply send the Return Setting instruction with data of 48. The device will reply with command #48 and data equal to the setting value.