Setting Cmd# T-HLA28
T-HLA28-S
T-HLA28-SV
Device Id na* 228
Microstep Resolution 37 64
Running Current 38 10
Hold Current 39 0
Mode 40 0
Target Velocity 42 2922
Acceleration 43 111
Range 44 282624
Maximum Relative Move 46 Range
Home Offset 47 0
Alias** 48 0
Antibacklash Distance na*** 10 steps
Antisticktion Distance na*** 10 steps

Notes:
* The device Id is not user configurable. It can however be returned using command #50.
** Aliases are not reset to 0 by command #36. To set an alias back to 0, you must use the set alias command #48.